Converging the switches

You want welland’s two switches to carry the VLANs the inventory says (after adding a switch, changing a port range, or replacing a switch), and to know the converge did what it should. ps1 has no per-port VLANs and nothing on this page applies to it: its switch, a Netgear FS728TPv2, is a Plus-series unit that the per-port design put out of scope (VLAN-per-port network design for fpgas.online, lines 6 and 25).

What the converge does

fpgas-switch-setup, the command-line tool in fpgas.online-poe, reads the switches: list from /etc/fpgas/switches.yml on the gateway, reads the switch’s state over SNMP, and writes only the difference: it creates the VLANs, sets the trunk ports’ memberships, sets each access port’s VLAN, and takes the access ports out of VLAN 1. Two rules bound what it can break (fpgas.online-poe README.md, main fcb4a2a):

  • It only ever writes VLANs 2101 to 2348 and the membership of the ports it owns, so VLAN 5 (switch management, on the house network) and the house uplink cannot be touched, even by a run that dies half-way.

  • It writes the trunks before the access ports, so a Pi’s port is never put in a VLAN that cannot yet reach the gateway.

Switch

Model

Management address

Access ports

Gateway side

1

Netgear GSM7252PS

10.1.5.23

1 to 40

port 47 to tweed’s eth-local; port 50 to switch 2

2

Netgear S3300-52X-PoE+

10.1.5.11

1 to 48

port 51 (1/xg51) to switch 1

(ansible/inventory/host_vars/fpgas.online.yml in fpgas.online-infra, main, read 2026-10-07; cabling confirmed from the switches’ own LLDP on 2026-08-22.)

Both are 52-port units. Both are managed over the house network’s VLAN 5, a separate path from the fpgas trunk: nothing management-related rides the trunk, and the provisioning tool never touches the house-facing port. Which board is on which port is on the Welland page.

The trunk ports differ from the design spec of 2026-08-14, which reserves ports 49-52 for trunks and sketches gateway_trunk_port: 49. The real cabling, confirmed from the switches’ own LLDP on 2026-08-22, is tweed’s eth-local into GSM 1/0/47 and GSM 1/0/50 into S3300 1/xg51. The spec’s access_ports: 48 on both switches is also not what shipped: switch 1 carries 40 access ports, switch 2 carries 48 (host_vars/fpgas.online.yml, main, read 2026-10-07).

The normal way: the whole playbook

The switch_vlans role of fpgas.online-infra installs the tool into /opt/fpgas-switch/venv, renders /etc/fpgas/switches.yml and runs the converge once per switch, with each switch’s write community from the vault. It runs as part of a deploy of the welland gateway, which is always the whole playbook, scoped only with --limit (fpgas.online-infra issue #157 removed the tags on 2 October 2026):

$ uv run ansible-playbook ansible/site.yml --limit fpgas.online

Deploying to a gateway has the whole procedure (vault password, pinned root, what to check after).

By hand, on the gateway

To see what the converge would do without the playbook, run the tool on the gateway as root. Check mode is the default and writes nothing; --apply writes.

$ # the write community of THIS switch, typed in, never in a file or a commit
$ export FPGAS_SWITCH_COMMUNITY='<switch-write-community>'
$ # check mode: prints the pending actions, writes nothing
$ /opt/fpgas-switch/venv/bin/fpgas-switch-setup --config /etc/fpgas/switches.yml --switch 1
$ /opt/fpgas-switch/venv/bin/fpgas-switch-setup --config /etc/fpgas/switches.yml --switch 1 --apply
$ # check again: expect no output and exit 0
$ /opt/fpgas-switch/venv/bin/fpgas-switch-setup --config /etc/fpgas/switches.yml --switch 1

The two switches have different write communities. Exit codes: 0 in step or applied, 2 check mode found differences, 1 an error.

Two things look like faults and are not (the prototype runbook in fpgas.online-infra, docs/superpowers/specs/2026-08-14-vlan-per-port-prototype-runbook.md): the switches sometimes answer a VLAN write with Error in packet or commitFailed although it applied (run again; only what is missing is written), and each SNMP operation takes about two seconds, so a 48-port converge runs for several minutes.

Afterwards

Check isolation: Checking isolation.